E8
Electrolux
Internal Communication Error / Control PCB Fault
Air fryer shows E8 and becomes unresponsive or shuts off unexpectedly.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Corrupted microcontroller firmware, Loose ribbon cable between display and main board, Failed main control PCB, Power supply instability on logic circuit
How to Fix / Troubleshooting
Safety first: Unplug the air fryer before opening the housing.
Steps:
- Power cycle: Unplug for 10–15 minutes to fully discharge internal capacitors. Plug back in and test. If E8 returns immediately, proceed.
- Inspect internal connectors: Remove the control panel cover and check the ribbon cable between the display/touch board and the main control PCB. Reseat the cable carefully, ensuring it is fully inserted and locked.
- Check for moisture: Look for signs of steam or moisture intrusion around the control panel. Dry the area thoroughly and allow the unit to sit in a warm, dry place for several hours before retesting.
- Board inspection: Examine the main control PCB for burnt components, corrosion, or cracked solder joints, especially around the microcontroller and voltage regulators. If damage is visible, replace the board.
Note: Firmware issues generally require board replacement; field reprogramming is not typically supported for consumer air fryers.