Farberware Basket Detection / Safety Switch Failure

Air fryer powers on but immediately shuts off or will not start when the basket is inserted.

Advertisements

Possible Causes

Misaligned or damaged basket rail, Broken plastic actuator that presses the microswitch, Failed basket safety microswitch, Loose switch wiring

How to Fix / Troubleshooting

Safety: Unplug the air fryer before inspecting the basket mechanism.

Steps to resolve basket detection issues:

  • Inspect basket fit: Ensure the basket and pan are correctly oriented and fully inserted. Check for bent metal or warped plastic that prevents full insertion.
  • Check actuator tab: Look inside the front opening for a small plastic tab or protrusion that contacts the internal switch. If broken or worn, the switch may not be engaged.
  • Access the switch: Remove the bottom cover to locate the basket safety microswitch near the front of the unit.
  • Test the switch: Manually press the switch lever and listen for a click. Use a multimeter to verify continuity changes when pressed. Replace the switch if it fails.
  • Adjust alignment: Slightly bend the metal bracket holding the switch (if present) so that the basket actuator reliably presses the switch when fully inserted.

Tip: Avoid overloading or forcing the basket, as this can bend rails and misalign the actuator.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Basket Safety Microswitch
Check Price on Amazon