E11
Frigidaire Internal Overcurrent / Short Circuit Protection

E11 error code and the unit shuts down shortly after starting

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted heating element, Shorted fan motor, Pinched wiring harness contacting chassis, Faulty control board triac or relay

How to Fix / Troubleshooting

Fire and Shock Hazard: Unplug the air fryer immediately and do not attempt to run it again until the short is identified and corrected.

  • Step 1 – Visual inspection: Remove the rear or bottom cover. Look for obvious signs of damage: burnt wires, melted insulation, or blackened areas on the control board.
  • Step 2 – Check wiring harness: Trace the main wiring from the power input to the heater and fan. Ensure no wires are pinched between metal panels or rubbing against sharp edges.
  • Step 3 – Isolate components (advanced): With the unit unplugged, disconnect the heater and fan motor one at a time and check their resistance. A reading near 0 Ω suggests a shorted component that must be replaced.
  • Step 4 – Inspect control board: Examine the heater and fan relays or triacs on the board for cracks or burn marks. If damaged, replace the control board.
  • Step 5 – Do not bypass fuses: If any internal fuses are blown, replace them only after correcting the underlying short. Never bypass a fuse with wire or foil.
  • Professional service recommended: Due to the risk of fire and shock, consider having a qualified technician perform these checks and repairs.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Heating Element Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements