E10
Gorenje Low Voltage / Power Supply Error

Display shows E10; unit may shut down mid-cycle or not start at all.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Unstable mains voltage, Failing internal SMPS power supply on PCB, Loose power cord connection, Oxidized mains terminals, Faulty line filter module

How to Fix / Troubleshooting

Safety first: Unplug the unit before inspection. Do not operate the air fryer on known unstable power sources.

  • Check outlet: Test the wall outlet with another appliance to confirm stable power. Avoid using long or undersized extension cords.
  • Inspect power cord and plug: Look for looseness, heat marks, or bent pins. Replace the power cord set if any defects are found.
  • Internal connections: Remove the housing and verify that the mains wires are firmly attached to the line filter and main control board terminals.
  • Power supply test: With appropriate safety precautions and only if you are qualified, measure the low-voltage outputs from the board (e.g., 5 V, 12 V) while the unit is powered. Fluctuating or low readings indicate a failing switch-mode power supply (SMPS) section on the main PCB.
  • Replace board or line filter: If the line filter is burnt or cracked, replace the EMI line filter module. If low-voltage rails are unstable, replace the main control board.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

EMI Line Filter Module
Check Price on Amazon