Kalorik Output Drive Failure on Control Board

Timer counts down but heater and fan do not run; unit appears 'on' but does not cook.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed heater relay and fan relay, Broken common supply to outputs, Firmware glitch, Loose output connectors

How to Fix / Troubleshooting

Safety first: Unplug the air fryer before opening the housing.

Steps to troubleshoot non-running heater and fan:

  • Confirm safety interlocks: Ensure the drawer is fully inserted and the basket safety switch is functioning (see E8 scenario).
  • Inspect output wiring: Remove the bottom cover and trace wires from the control PCB to the heater and fan. Ensure all connectors are firmly seated.
  • Check for board damage: Look for burnt or cracked solder joints around the heater and fan relays or triacs.
  • Replace control board: If the timer and display work but neither heater nor fan receive power, the main control PCB is likely defective. Replace it with a Kalorik-specific board.

Because both outputs are affected, focus on the common control electronics rather than individual components.