Kenmore Unstable internal power or poor electrical connection

Display and lights flicker or dim during operation.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose power cord,Failing main control board power supply,Loose neutral connection,Defective line filter board

How to Fix / Troubleshooting

Safety first: Unplug the unit before opening any panels.

  • Check outlet and plug: Ensure the plug is fully inserted and the outlet is not worn. Try a different outlet.
  • Avoid power strips: Plug the air fryer directly into the wall outlet to reduce voltage drop.
  • Inspect internal connections: Remove the rear or bottom cover and verify all power connectors are tight, especially at the line filter board and main control board.
  • Look for heat damage: Discolored connectors or melted plastic indicate overheating; replace the affected harness and connector.
  • Replace control or filter board: If flickering persists and connections are solid, replace the line filter board or main control board as indicated by your model's design.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Line Filter Board
Check Price on Amazon

We may earn a commission from links on this page.