Possible Causes

Worn basket latch, Misaligned safety switch, Broken plastic tab that actuates switch, Loose switch mounting bracket

How to Fix / Troubleshooting

Safety first: Unplug the fryer before working near the basket cavity.

Steps:

  • 1. Inspect latch: Examine the basket handle latch and any protruding tabs that engage the internal switch. Replace the basket if the latch is worn or broken.
  • 2. Check switch alignment: Open the housing and locate the basket safety switch. Ensure it lines up with the basket tab when inserted. Adjust the switch bracket if necessary.
  • 3. Tighten mounting screws: Secure any loose screws holding the switch bracket or front frame.
  • 4. Test engagement: With the unit unplugged, insert the basket and listen/feel for a distinct click from the switch. If no click, adjust or replace the switch.
  • 5. Reassemble and test: Plug in and run a cycle, gently moving the basket handle to ensure the unit does not shut off unexpectedly.

Warning: Do not bypass the safety switch; it is essential for safe operation.