Klarstein
Basket Latch / Safety Switch Engagement Issue
Basket does not lock properly; cooking stops when the basket is slightly moved.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Worn basket latch, Misaligned safety switch, Broken plastic tab that actuates switch, Loose switch mounting bracket
How to Fix / Troubleshooting
Safety first: Unplug the fryer before working near the basket cavity.
Steps:
- 1. Inspect latch: Examine the basket handle latch and any protruding tabs that engage the internal switch. Replace the basket if the latch is worn or broken.
- 2. Check switch alignment: Open the housing and locate the basket safety switch. Ensure it lines up with the basket tab when inserted. Adjust the switch bracket if necessary.
- 3. Tighten mounting screws: Secure any loose screws holding the switch bracket or front frame.
- 4. Test engagement: With the unit unplugged, insert the basket and listen/feel for a distinct click from the switch. If no click, adjust or replace the switch.
- 5. Reassemble and test: Plug in and run a cycle, gently moving the basket handle to ensure the unit does not shut off unexpectedly.
Warning: Do not bypass the safety switch; it is essential for safe operation.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Basket Safety Microswitch
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements