Midea Relay Chatter / Unstable Heater Control

Clicking noise from the control area; heater cycles erratically.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Weak relay coil on PCB, Poor solder joints on relay pins, Unstable power supply voltage, Faulty temperature sensor feedback

How to Fix / Troubleshooting

Safety first: Unplug before accessing the PCB.

  • Step 1 – Observe behavior: Note if clicking is rapid and irregular, or normal slow cycling. Rapid chatter indicates a fault.
  • Step 2 – Inspect solder joints: On the main PCB, examine the heater relay pins for cracked or dull solder. Reflow solder if you are qualified, or replace the board.
  • Step 3 – Check sensor connection: Ensure the NTC sensor connector is secure; intermittent readings can cause relay chatter.
  • Step 4 – Replace PCB: If chatter persists, replace the main control board to prevent relay failure and overheating.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements