E8
Midea Keypad / Touch Panel Communication Error

E8 error code appears and the unit will not respond to temperature or time adjustments.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose ribbon cable between touch panel and PCB, Damaged touch control panel, Corroded keypad connector, Failed main PCB interface circuit

How to Fix / Troubleshooting

Safety first: Unplug the air fryer before removing the control panel. Capacitors on the PCB can retain charge; avoid touching exposed contacts.

  • Step 1 – Power reset: Unplug for 5–10 minutes, then reconnect. If E8 clears temporarily, the issue may be intermittent connection.
  • Step 2 – Inspect ribbon cable: Remove the front control panel bezel. Locate the flat ribbon cable from the touch panel to the main PCB. Ensure it is fully inserted and locked in place.
  • Step 3 – Clean contacts: If the ribbon is removable, gently clean the contacts with isopropyl alcohol and a lint‑free swab. Reinsert firmly.
  • Step 4 – Check for cracks: Examine the touch panel board for cracks or liquid damage. If any traces are broken, replace the touch control panel assembly.
  • Step 5 – PCB diagnosis: If the panel and cable are good but E8 persists, the interface IC on the main PCB may be faulty. Replace the main control board.
Advertisements

Repair Difficulty

Medium 3/5