Morphy Richards Temperature Regulation Failure

Air fryer overheats, burning food even at low temperature settings.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

NTC sensor detached from mounting point, Shorted NTC sensor reading low, Stuck heater relay on main PCB, Incorrect calibration or faulty MCU

How to Fix / Troubleshooting

Safety first: Unplug and let the unit cool fully. Overheating can be a fire risk.

  • Check sensor placement: Access the interior and locate the NTC sensor near the heater or air outlet. Ensure it is firmly clipped or screwed to the metal surface and not hanging loose.
  • Test sensor resistance: Measure the NTC at room temperature and compare to expected values (consult service data if available). Replace if readings are significantly lower than normal.
  • Inspect relay contacts: On the main PCB, check if the heater relay contacts are welded closed (heater always on). If so, replace the main control PCB.
  • Functional test: After repairs, run the unit with an oven thermometer inside to verify that set temperatures roughly match actual temperatures.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Cabinet NTC Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.