E9
Morphy Richards
Internal Communication / MCU Error
E9 is displayed and the unit shuts down shortly after starting.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Corrupted firmware on main PCB, Loose display-to-main-board ribbon cable, Electrical noise or surge damage, Faulty main microcontroller
How to Fix / Troubleshooting
Safety first: Unplug the unit before opening.
- Power cycle: Disconnect from mains for 10 minutes to allow capacitors to discharge, then reconnect and test. This can clear transient MCU faults.
- Check internal connectors: Open the control panel and verify that the ribbon cable between the display board (if separate) and the main PCB is fully seated and not damaged.
- Inspect for moisture: Look for signs of condensation or liquid ingress around the control panel. Dry thoroughly and clean with isopropyl alcohol if needed.
- Firmware/PCB replacement: If E9 persists, the main PCB may require replacement. Morphy Richards typically supplies the control board as a complete assembly rather than offering firmware reflash tools to consumers.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Main Control PCB
Check Price on Amazon