P2
Morphy Richards
Interruption / Basket Removal Error
P2 error and the unit stops partway through cooking, often when the basket is removed and reinserted.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Sticky basket switch not re‑engaging, Debris around switch actuator, Loose switch wiring, Faulty logic on main PCB interpreting switch state
How to Fix / Troubleshooting
Safety first: Unplug before accessing internal switches.
- Clean basket area: Remove crumbs and grease from the basket rails and the area where the switch actuator moves. Sticky residue can prevent full travel.
- Check switch movement: With the cover removed, manually operate the basket switch and listen for a crisp click. If sluggish, replace the microswitch.
- Secure wiring: Ensure the switch wires are not loose or intermittently disconnecting when the unit warms up or vibrates.
- PCB logic: If the switch tests good but P2 persists, the main PCB may misread the signal. Replacement of the control board may be required.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Basket / Door Interlock Microswitch
Check Price on Amazon
We may earn a commission from links on this page.