Moulinex Temperature Regulation Failure

Air fryer overheats; exterior becomes very hot to touch, and food burns quickly even at low settings.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

NTC sensor detached from heater area, Shorted sensor reading low temperature, Stuck heater relay on PCB, Bypassed or failed thermal cut-out

How to Fix / Troubleshooting

Safety first: Unplug immediately and do not use the fryer until repaired. Overheating is a fire hazard.

  • Step 1 – Inspect sensor placement: Open the housing and locate the NTC sensor. Ensure it is firmly clipped to the heater shroud or designated bracket and not hanging away from the heat source.
  • Step 2 – Test sensor: Measure resistance at room temperature and compare to expected values. A shorted sensor (very low resistance) can cause the controller to overheat the unit.
  • Step 3 – Check relay: Inspect the heater relay on the PCB. If contacts are welded closed, the heater may stay on continuously. Replace the PCB or relay.
  • Step 4 – Verify thermal cut-out: Test continuity of the thermal cut-out. If it has been bypassed or replaced with an incorrect part, restore the correct Moulinex-specified component.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

NTC Temperature Sensor Probe
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements