Oster Intermittent Basket / Door Switch Contact

Oster air fryer shuts off when the basket is bumped or moved slightly during cooking.

Advertisements

Possible Causes

Loose or misaligned basket detection microswitch, Worn actuator tab on basket, Loose switch wiring, Cracked switch housing

How to Fix / Troubleshooting

Safety: Allow the unit to cool before adjusting internal switches.

  • Observe behavior: Gently wiggle the basket handle during operation. If the unit shuts off, the safety switch is too sensitive or loose.
  • Inspect basket tab: Check the plastic tab that engages the switch for wear or damage. Replace the basket if the tab is worn down.
  • Adjust switch (advanced): Access the basket switch and slightly adjust its position so it is fully engaged when the basket is inserted. Tighten mounting screws.
  • Replace switch: If the switch is intermittent when tested with a multimeter, replace it with an Oster-compatible microswitch.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Basket Detection Microswitch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements