E17
Philips Sensor Calibration / Configuration Error

Display shows E17; smart features or app control partially work but some functions are disabled.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect factory calibration data, Corrupted configuration memory, Replacement board not programmed for model, Service mode not exited correctly

How to Fix / Troubleshooting

Safety first: Disconnect from mains before accessing internal electronics.

Steps:

  • User reset: Perform a factory reset from the settings menu (if available). Power cycle and test again.
  • Board identity: If a control board was recently replaced, verify that the part number exactly matches the Philips model. Some boards require model-specific programming.
  • Service calibration: Certain models need sensor calibration via service tools. If E17 appears after board replacement, contact Philips service or a qualified technician to perform calibration.
  • Board replacement: If configuration memory is corrupted and cannot be reset, the main control board may need replacement.

Warning: Do not attempt undocumented service-mode changes; this can disable safety features.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Main Control Board
Check Price on Amazon