E8
Philips
Internal Communication Error (Main Board to UI Board)
Display shows E8; unit may not start or may shut down mid-cycle without heating properly.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Loose or damaged communication cable between boards, Oxidized connectors, Faulty main control board, Faulty user interface board
How to Fix / Troubleshooting
Safety first: Disconnect from mains before opening the housing.
Steps:
- Reset: Unplug for 10 minutes and reconnect. If E8 clears temporarily but returns, suspect an intermittent connection.
- Inspect cables: Open the unit and locate the harness or ribbon cable linking the main control board to the display/touch board. Reseat connectors and check for bent pins or damaged insulation.
- Clean contacts: If there is visible oxidation, gently clean connector contacts with electronic contact cleaner and allow to dry fully.
- Board substitution: If possible, test with a known-good UI board or main board. Replace the defective board identified by substitution or by visible damage.
Warning: Avoid pulling on cables; always grip connectors to prevent damage.
Advertisements
Repair Difficulty
Hard