E8
Russell Hobbs
Low Voltage / Power Supply Fault
E8 displayed; unit may power on but controls are unresponsive or shut down quickly.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty internal SMPS power supply on control PCB, Loose mains connector, Damaged power cord, Overheated or failed varistor or fuse on PCB
How to Fix / Troubleshooting
Safety: Unplug the air fryer. Internal power supply components are connected to mains voltage; only attempt advanced checks if you are competent with electrical safety.
- External power check: Test the wall outlet with another appliance. Avoid using long extension leads or multi-way adaptors that may cause voltage drop.
- Inspect power cord: Check the Russell Hobbs power cord for cuts, kinks, or burn marks. If damaged, replace the power cord set with the correct rating.
- Check mains inlet: If your model has a detachable mains inlet, ensure it is firmly seated and not loose.
- Open housing (advanced): Remove covers to access the control PCB. Visually inspect for burnt components, bulging capacitors, or cracked solder joints around the transformer or power supply section.
- Fuse/varistor check: Some boards include a small fuse or fusible resistor. Test continuity and replace only with identical rated components if blown.
- PCB replacement: If the power supply section shows damage or E8 persists, replace the entire control PCB / power module rather than attempting component-level repair unless you are qualified.
- Reassemble and test: After any cord or PCB replacement, reassemble and test for stable operation without E8.
Advertisements
Repair Difficulty
Professional Required
5/5