Sage Temperature control runaway / sensor not reading

Air fryer overheats, burning food even at moderate settings.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

NTC sensor detached from cavity, Sensor wiring broken intermittently, High‑limit thermostat stuck closed at too high a temperature, Control board triac or relay stuck on

How to Fix / Troubleshooting

Safety first: Unplug immediately if you suspect overheating. Allow full cool‑down before inspection.

  • Check for error codes: Some models will show E2/E3 when overheating. If no code appears, proceed with caution.
  • Inspect sensor mounting: Confirm the temperature sensor is still fixed in its bracket and not hanging away from the hot zone.
  • Check wiring: Look for partially broken or heat‑damaged sensor wires that may cause intermittent readings.
  • Test sensor resistance: Compare resistance at room temperature to the expected value from service data (or to a new sensor). Replace if out of range.
  • Control board: If the sensor and wiring are correct but the heater remains on excessively, the control board's switching device may be stuck and the board should be replaced. Do not continue using an air fryer that overheats.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

NTC Temperature Sensor Probe
Check Price on Amazon