Severin No Power / Dead Appliance

Air fryer does not power on at all; no lights or display when plugged in.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blown internal fuse on mains input, Faulty Severin power cord, Failed main control PCB power supply, Loose mains terminal connections

How to Fix / Troubleshooting

Safety first: Ensure the appliance is unplugged before opening. Mains circuits can be lethal.

  • Check outlet and cord: Test the wall outlet with another device. Inspect the Severin power cord for cuts or burn marks. Replace the cord if damaged.
  • Inspect internal fuse: Open the housing and locate the small glass or ceramic fuse near the mains input. Remove and test with a multimeter for continuity. If blown, replace with the same type and rating after checking for shorts.
  • Check mains connections: Verify that all spade connectors from the mains inlet to the PCB are tight and not oxidized.
  • Examine power supply section: On the main PCB, look for burnt components or bulging capacitors in the SMPS area. If present, replace the main control PCB.

Warning: If the new fuse blows immediately, there is likely a shorted component (e.g., bridge rectifier, MOV, or primary switch). Do not keep replacing fuses; seek professional repair.