E5
Sunbeam Power Supply / Voltage Abnormality Detection

E5 error appears during preheat or mid-cycle; unit stops heating and may beep continuously.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Low or high line voltage, Loose mains cord connection inside unit, Failing main control PCB power supply, Damaged surge components on PCB

How to Fix / Troubleshooting

Safety: Unplug the air fryer before any inspection. Do not operate the unit on damaged outlets or extension cords.

Steps:

  • 1. Check outlet: Plug another appliance (like a kettle) into the same outlet to confirm stable power. Avoid using long or undersized extension cords.
  • 2. Inspect power cord: Examine the Sunbeam power cord for cuts, kinks, or burn marks. If damaged, the cord set must be replaced by a qualified technician.
  • 3. Internal cord connection: Remove the base cover and verify that the cord strain relief is intact and that the live, neutral, and earth wires are firmly secured to the terminal block or PCB.
  • 4. PCB inspection: Look for swollen capacitors, burned resistors, or cracked solder joints on the main control PCB, especially near the power input section. Any visible damage usually means the board should be replaced, not repaired at home.
  • 5. Test again: After reseating connections, reassemble and test. If E5 recurs immediately and your household voltage is normal, the internal power supply on the PCB is likely faulty.

Warning: Do not attempt to modify or bypass the internal power circuitry. High voltages are present and can cause serious injury.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Main Control PCB
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements