Sunbeam Fan Motor Bearing Wear

High-pitched squealing noise when the air fryer is running.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Dry or worn fan motor bearings, Misaligned fan blade rubbing on shroud, Debris lightly contacting fan edge

How to Fix / Troubleshooting

Safety: Unplug and cool the unit before inspection.

Steps:

  • 1. Confirm source: The squeal usually comes from the top rear where the fan motor is located.
  • 2. Access fan area: Remove the necessary covers to reach the fan and motor.
  • 3. Check blade clearance: Ensure the fan blade is not rubbing against the metal shroud or guard. Gently adjust if needed.
  • 4. Inspect bearings: Spin the fan by hand. A squeal or rough feel indicates worn bearings. The motor is typically sealed and not serviceable; replace the motor assembly.
  • 5. Reassemble and test: After replacing the motor, reassemble all covers securely and test for quiet operation.

Note: Do not apply household oil to the motor; it can attract dust and is not a permanent fix.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Convection Fan Motor
Check Price on Amazon