E2
Tefal
NTC Temperature Sensor Short Circuit / Overrange
Air fryer stops heating and displays E2 during preheat or cooking, fan may still run.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Shorted NTC sensor on heater housing, Sensor wires shorted to chassis, Melted sensor insulation from overheating, Faulty main control board interpreting sensor signal
How to Fix / Troubleshooting
Safety first: Disconnect the air fryer from power and let it cool fully before inspection.
- Reset and cool down: If the unit was used for a long cycle, allow at least 30 minutes to cool, then plug back in and test. E2 can sometimes be triggered by extreme over-temperature.
- Inspect air vents: Make sure the rear and top vents are not blocked. Overheating from poor ventilation can damage the sensor wiring.
- Internal inspection (advanced users):
- Remove the top cover to access the heater and sensor area.
- Look for melted insulation or wires touching the metal heater frame.
- Gently separate any wires that are touching hot metal and check for bare copper. If insulation is damaged, the sensor harness should be replaced.
- Sensor replacement: If the sensor body is cracked, charred, or reads near 0 Ω on a multimeter (shorted), it must be replaced with a compatible Tefal NTC sensor.
- Do not bypass: Never bypass or short the sensor to clear the error; this disables temperature safety and can cause fire.