Ultima Cosa Start Command / Safety Interlock Not Satisfied

Unit powers on but will not start cooking when Start button is pressed.

Advertisements

Possible Causes

Basket not fully inserted, Faulty start button on touch panel, Basket interlock switch not closing, Control board logic fault

How to Fix / Troubleshooting

Safety first: Unplug the unit before mechanical or electrical checks.

  • Confirm basket position: Remove and firmly reinsert the basket drawer. Ensure it is flush with the front panel.
  • Test other buttons: If other buttons respond but Start does not, the Start key on the touch panel may be faulty. Replace the touch control panel assembly.
  • Check interlock switch: Verify the basket interlock switch operates correctly with a multimeter as described in interlock-related entries.
  • Control reset: Unplug for 10 minutes to reset the control. If the issue persists with a good panel and switch, replace the main control PCB.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Touch Control Panel Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements