Xiaomi Temperature regulation failure

Air fryer overheats and burns food even at low temperature settings.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted or drifted NTC temperature sensor,Sensor detached from cavity wall,Heater relay stuck closed,Main control board temperature control failure

How to Fix / Troubleshooting

Safety first: Unplug the unit and allow it to cool. Do not continue using an overheating appliance.

Checks:

  • Verify settings: Confirm you are not accidentally using a high-temperature preset.
  • Sensor inspection: Access the cavity sensor and ensure it is firmly attached and not touching the heater.
  • Sensor test (experienced users): Measure the NTC resistance at room temperature and compare to specifications. A very low resistance may cause the board to overdrive the heater.
  • Relay check: On the main board, inspect the heater relay. If the heater remains on even when the unit is off or paused, the relay contacts may be welded closed.

Corrective actions:

  • Replace the NTC sensor if readings are out of range or it is damaged.
  • Replace the main control board if the heater relay is stuck or the control logic is faulty.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

NTC Temperature Sensor Probe
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements