E19
Alpha
Plate Heat Exchanger Temperature Differential Fault
Boiler shows E19; may occur intermittently, often during hot water draw-off.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked plate heat exchanger, Limescale build-up, Poor primary circulation, Faulty DHW NTC sensor
How to Fix / Troubleshooting
Safety: Isolate power and water supplies. Components may be hot.
- Check system pressure and circulation: Ensure correct pressure and that radiators heat evenly, indicating good primary flow.
- Descale plate heat exchanger (qualified person): Remove the plate heat exchanger and flush it with a suitable descaling solution until flow is restored.
- Clean system filter: If fitted, clean the Alpha magnetic filter to improve primary water quality.
- Verify DHW sensor: Test and replace the DHW NTC if readings are unstable.
Severe scaling may require replacement of the plate heat exchanger.