Ariston
Chronic Pressure Loss
Boiler frequently loses pressure and needs topping up
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Hidden leak in CH pipework, Dripping pressure relief valve, Failed expansion vessel, Micro-leaks at radiator valves
How to Fix / Troubleshooting
Safety: Do not repeatedly overfill the system; this can damage components.
- Inspect for visible leaks: Check all radiators, valves, and accessible pipes for damp patches or staining.
- Check PRV discharge: Look at the end of the pressure relief valve discharge pipe outside. If it's wet or dripping, the valve is passing and may need replacement.
- Expansion vessel test (basic): If pressure rises very high when hot and drops to zero when cold, the expansion vessel is likely failed. This requires an engineer to recharge or replace.
- Monitor pressure: After topping up to 1.2 bar, note how quickly pressure drops. Rapid loss suggests a significant leak that must be located and repaired professionally.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Expansion Vessel
Check Price on Amazon