Air in System / Bypass Flow Noise
Boiler operates but makes a constant trickling or running water noise
Advertisements
Possible Causes
Air trapped in radiators or boiler, Automatic bypass valve set too high, High pump speed, Partially closed valves causing high velocity
How to Fix / Troubleshooting
Safety: Allow system to cool before bleeding radiators.
- Bleed system: Bleed all radiators and the pump (if possible) to remove air.
- Check pressure: After bleeding, top up to 1.2–1.5 bar.
- Adjust pump speed: If your Ariston pump has multiple speeds, try reducing the speed to minimise noise.
- Bypass valve: An engineer can adjust the automatic bypass valve to reduce unnecessary flow noise.
Advertisements
Repair Difficulty
Easy
2/5