Ariston DHW Priority / Diverter Valve Fault

Boiler runs for heating but hot water is lukewarm or cold

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Diverter valve stuck in CH position, Blocked DHW plate heat exchanger, Faulty DHW flow sensor, Incorrect boiler settings

How to Fix / Troubleshooting

Safety: Turn off power and isolate water before removing any water components.

  • Check boiler display: Many Ariston models show a tap symbol when DHW is demanded. If this does not appear when a hot tap is opened, the DHW flow sensor may be faulty.
  • Diverter valve test: When a hot tap is opened, the CH flow pipe should cool and DHW pipes should heat. If CH stays hot and DHW cold, the diverter valve is likely stuck.
  • Descale plate heat exchanger: If DHW is only lukewarm at high flow, the DHW plate heat exchanger may be scaled and require descaling or replacement.
  • Engineer repair: Diverter valve and plate heat exchanger work should be done by a qualified engineer.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Diverter Valve Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements