103
Ariston Primary Circuit Circulation Fault / Overtemperature

Boiler shows 103, frequent lockouts, radiators only warm at top or not heating fully

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked primary circuit, Sludged radiators or pipework, Partially blocked primary heat exchanger, Failing circulation pump

How to Fix / Troubleshooting

Safety: Turn off power and allow the boiler to cool before touching pipework.

  • Check all radiator valves: Ensure TRVs and lockshield valves are open to allow circulation. A closed circuit can cause overheat and error 103.
  • Bleed radiators: Remove trapped air from all radiators. Top up system pressure as needed.
  • Check pump speed and operation: On the Ariston circulation pump, verify the speed setting (if adjustable) is not on the lowest setting for a large system. Listen for unusual noises or grinding that indicate pump wear.
  • Feel flow and return temperatures: With heating demand, carefully touch (briefly) the flow and return pipes. If flow is extremely hot and return is very cool, circulation is poor, suggesting blockage or pump failure.
  • System cleaning: Add a central heating cleaner via a radiator or dosing point and run the system as per product instructions, then flush and refill with inhibitor. Severe sludge may require professional power flushing.
  • Reset boiler: After improving circulation, reset the boiler. Persistent 103 faults require an engineer to check the primary heat exchanger and pump performance.