105
Ariston
Primary Circuit Overheat / Kettling
Boiler shows 105, frequent overheat lockouts, loud kettling noises from boiler
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Limescale in primary heat exchanger, Poor circulation due to pump wear, Sludge in system, Incorrectly set boiler output for system size
How to Fix / Troubleshooting
Safety: Turn off power and gas before removing covers. Surfaces may be very hot.
- Check system pressure and bleed: Ensure pressure is 1.0–1.5 bar cold. Bleed radiators and the pump to remove air.
- Listen for kettling: Boiling or banging noises from the primary heat exchanger indicate limescale or poor flow. This is common in hard water areas.
- Descale primary circuit: A professional can circulate a descaling solution through the primary heat exchanger. As a homeowner, you can add inhibitor and cleaner to reduce further build-up, but internal descaling should be done by an engineer.
- Check pump performance: If radiators heat slowly and the boiler overheats, the pump may be weak. Replacement of the Ariston pump assembly is often required.
- Adjust boiler output: On some Ariston models, the maximum CH output can be reduced via the control panel or PCB potentiometer. Setting it too high for a small system can cause short cycling and overheating. Refer to the installation manual; adjustments should be made by a competent person.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Primary Heat Exchanger