109
Ariston
High System Pressure / Overpressure
Boiler shows 109, pressure rises quickly when heating, water discharges from safety valve
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Overfilled system via filling loop, Failed or uncharged expansion vessel, Faulty pressure relief valve not reseating, Filling loop left open
How to Fix / Troubleshooting
Safety: Hot water may discharge from the safety valve pipe; keep clear of discharge point.
- Check pressure cold: When the system is cold, note the pressure. It should be around 1.0–1.5 bar. If above 2.0 bar, the system is overfilled.
- Reduce pressure: Bleed water from a radiator using a bleed key into a container until the pressure drops to about 1.2 bar.
- Inspect filling loop: Ensure the filling loop valves are fully closed and the flexible hose is removed if external. A passing valve can slowly overfill the system.
- Expansion vessel test: If pressure rises above 3 bar when hot and the safety valve discharges, the expansion vessel may have lost air charge. A professional can check and recharge via the Schrader valve or replace the vessel.
- Safety valve: Once a pressure relief valve has discharged, it may not reseal properly and can drip. Replacement by an engineer is recommended.