112
Ariston Return Temperature Sensor Fault

Boiler displays 112, intermittent operation, sometimes shuts down during long runs

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective return NTC sensor, Loose sensor clip or poor contact, Damaged wiring harness, PCB input fault

How to Fix / Troubleshooting

Safety: Isolate power before accessing internal components.

  • Locate return NTC: Find the return temperature sensor on the return pipe. Ensure it is firmly attached and properly clipped.
  • Inspect wiring: Check for damaged insulation, loose connectors, or corrosion. Reseat connectors at both the sensor and PCB.
  • Resistance test: With power off, disconnect the sensor and measure resistance. Compare to Ariston's chart. Replace if readings are out of range.
  • Replace sensor: Fit a new genuine Ariston return NTC sensor if faulty. Ensure good thermal contact.
  • Reset and monitor: Restore power, reset the boiler, and monitor for recurrence of 112. Persistent faults may indicate PCB issues requiring professional attention.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Return Temperature Sensor (NTC)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements