301
Ariston
User Interface / Control Panel Communication Fault
Boiler displays 301, no response to controls, some LEDs may flash
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Loose ribbon cable between PCB and display, Faulty control panel PCB, Moisture ingress into controls, Main PCB communication failure
How to Fix / Troubleshooting
Safety: Isolate power before removing the front panel or control fascia.
- Power cycle: Turn off the boiler at the fused spur for 30 seconds, then turn back on. This can clear temporary communication glitches.
- Inspect connections: Remove the front cover and carefully check the display ribbon cable and connectors between the main PCB and user interface. Reseat them firmly.
- Check for moisture: Look for signs of water ingress around the control panel. If present, the source of the leak must be found and fixed, and the affected PCB may need replacement.
- Replace interface: If the display remains dead or erratic, a new Ariston user interface board may be required. This should be fitted by a competent person.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
User Interface PCB
Check Price on Amazon
We may earn a commission from links on this page.