304
Ariston CH Demand Signal Fault

Boiler shows 304, hot water works but heating does not respond to thermostat

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty room thermostat, Broken CH demand wiring, Stuck diverter valve in DHW position, PCB not recognising CH request

How to Fix / Troubleshooting

Safety: Turn off power before accessing wiring or valves.

  • Check thermostat settings: Ensure the room thermostat is calling for heat (temperature set above room temperature, schedule active).
  • Bypass test: If safe and permitted, link the CH demand terminals at the boiler. If heating starts, the thermostat or its wiring is faulty.
  • Diverter valve check: If radiators stay cold but hot water is fine, the diverter valve may be stuck in DHW mode. Feel the CH flow pipe from the boiler when CH is demanded; if it stays cold, the valve is suspect.
  • Engineer repair: Diverter valve motor head or cartridge replacement should be done by a professional.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Diverter Valve Assembly
Check Price on Amazon