E07
Attack
Water Pressure Sensor / Switch Fault
Boiler shows E07 and will not operate; may be associated with very low or very high system pressure.
Advertisements
Possible Causes
Low system pressure in Attack sealed system, Faulty water pressure sensor or pressure switch, Blocked pressure sensing tube, Wiring fault between sensor and PCB
How to Fix / Troubleshooting
Safety: Allow the system to cool before topping up pressure. Use only clean mains water via the filling loop.
Steps:
- Check pressure gauge: Confirm the reading on the Attack boiler display or mechanical gauge. If below the recommended level (often 1.0 bar cold), top up using the filling loop until correct.
- Bleed air: After topping up, bleed radiators and recheck pressure, adjusting as needed.
- Inspect for leaks: Look around the boiler, safety valve discharge pipe, and radiators for signs of water loss that could cause low pressure.
- Sensor inspection: Locate the water pressure sensor on the hydraulic block. Check for leaks, corrosion, or a blocked sensing port. Gently tap the sensor body to free any stuck diaphragm.
- Reset boiler: After correcting pressure, reset the boiler and observe if E07 clears.
Technician: If the code remains with correct pressure, the sensor or PCB likely needs replacement by an authorized Attack service provider.