E18
Attack
Outdoor Temperature Sensor Fault
Boiler displays E18; may be associated with external sensor or weather compensation probe.
Advertisements
Possible Causes
Open or shorted Attack outdoor sensor, Damaged cable between sensor and boiler, Incorrect sensor wiring polarity, Faulty PCB sensor input
How to Fix / Troubleshooting
Safety: Isolate power before working on wiring.
Steps:
- Locate outdoor sensor: Find the Attack external temperature sensor on the outside wall. Check that it is intact and not waterlogged.
- Inspect cable: Follow the cable back to the boiler, looking for cuts or crushed sections.
- Check connections: At the boiler terminal strip, ensure the sensor wires are firmly clamped in the correct terminals.
- Temporary bypass: If allowed by the manual, you may disable weather compensation in the control menu to restore operation until the sensor is replaced.
Technician: If replacing the sensor does not clear E18, the PCB input should be tested by a professional.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Outdoor Temperature Sensor
Check Price on Amazon