01
Biasi Ignition Failure / Flame Not Detected

Boiler locks out with code 01, burner does not ignite, red lockout light on control panel.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty ignition electrode, Incorrect electrode gap or contamination, Faulty flame detection (ionisation) electrode, Gas valve not opening or low gas pressure

How to Fix / Troubleshooting

Safety first: Turn off electrical power to the boiler and close the gas isolation valve before removing any covers. Only a Gas Safe (or equivalent) registered engineer should work on gas-carrying components.

  • Reset the boiler: Press the reset button as per the Biasi manual and observe if the boiler attempts ignition (you should hear the fan and clicking from the igniter).
  • Check gas supply: Ensure the gas isolation valve under the boiler is open and other gas appliances in the property work correctly. If not, contact your gas supplier.
  • Inspect ignition electrode: With power and gas off, remove the combustion chamber cover. Check the ignition electrode on the Biasi burner assembly for cracks, heavy carbon deposits, or damage. Clean gently with fine emery cloth and ensure the ceramic is intact.
  • Check electrode gap and position: Compare the electrode position and gap to the Biasi service manual. The tips must be correctly aligned over the burner for reliable ignition.
  • Inspect ionisation (flame) electrode: Clean the probe, check the cable and connection back to the PCB for signs of burning or loose terminals.
  • Gas valve operation (engineer only): A qualified engineer should verify that the gas valve coil is energised during ignition and that inlet and burner pressures match Biasi specifications.
  • If lockouts persist: Do not keep resetting. Contact a qualified boiler engineer to test ignition components, gas valve, and PCB.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Ignition Electrode and Flame Sensor Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements