02
Biasi
Flame Loss During Operation
Boiler displays error 02 and shuts down shortly after starting, burner stops unexpectedly.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Unstable gas supply pressure, Faulty flame detection electrode or lead, Blocked burner or incorrect combustion, Faulty gas valve modulation control
How to Fix / Troubleshooting
Safety: Isolate electrical power and close the gas valve before removing the boiler case. Gas and combustion checks must be done by a qualified engineer.
- Check for pattern: Note if the boiler runs for a few seconds or minutes before 02 appears. This helps identify if the issue is combustion stability or control-related.
- Verify flue and air intake: Ensure the Biasi concentric flue terminal is not blocked by debris, snow, or vegetation. A restricted flue can cause poor combustion and flame loss.
- Inspect burner and electrodes: With the combustion chamber open, check the burner surface for corrosion or debris. Clean as per Biasi instructions. Clean and inspect the flame electrode and its cable.
- Check system gas supply: Confirm other gas appliances operate normally. If they also cut out, contact the gas supplier.
- Engineer checks: A technician should measure gas inlet pressure, burner pressure, and combustion (CO/CO₂) to ensure the gas valve and burner are correctly set. They should also verify the flame signal at the PCB.
- Do not bypass safety devices: Never attempt to bridge or bypass flame sensing or gas valve controls.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Flame Detection Electrode
Check Price on Amazon