04
Biasi
Primary Overheat Thermostat Tripped
Boiler displays error 04 and will not start, often accompanied by overheat light or very hot casing.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked primary heat exchanger, Failed pump or no circulation, Airlock in system, Faulty overheat thermostat or sensor
How to Fix / Troubleshooting
Safety: Turn off power and allow the boiler to cool fully before touching any pipework or internal components.
- Check system pressure: On sealed Biasi systems, ensure the pressure gauge reads around 1.0–1.5 bar when cold. If low, top up via the filling loop following the manual.
- Bleed radiators: Air in the system can cause local overheating. Bleed all radiators and any manual air vents near the boiler.
- Check pump operation: When there is a heat demand, place a hand on the circulation pump. You should feel vibration and slight warmth. If it is silent and cold, it may be seized or not powered.
- Reset overheat stat: Some Biasi models have a manual reset overheat thermostat on the primary heat exchanger. Once cooled, press the reset button if accessible as per the manual.
- Engineer inspection: If the fault recurs, a technician should check for sludge-blocked heat exchanger, verify pump performance, and test the NTC sensors and overheat stat.
Advertisements
Repair Difficulty
Hard
4/5