05
Biasi Air Pressure Switch Not Proving

Boiler shows error 05, no heating or hot water, fan may run but no ignition sequence completes.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty air pressure switch, Blocked or incorrectly installed flue, Blocked venturi or fan outlet, Split or disconnected pressure tubing

How to Fix / Troubleshooting

Safety: Isolate power and gas. Flue and combustion checks must be done by a qualified engineer.

  • Check flue terminal externally: Ensure the Biasi flue outlet is not blocked by grills, covers, or debris.
  • Inspect condensate system: A blocked or frozen condensate pipe can cause backpressure. Thaw frozen sections with warm (not boiling) water and clear any blockages.
  • Visual check of pressure tubes: With the case removed, inspect the silicone tubes from the fan/venturi to the air pressure switch. Refit any loose tubes and replace if perished or split.
  • Engineer tests: A technician should test continuity and switching of the air pressure switch with a multimeter, verify correct flue length and configuration, and clean the venturi if partially blocked.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Air Pressure Switch