10
Biasi
Primary Circuit Overtemperature / Flow Blockage
Boiler displays error 10, often associated with rapid temperature rise and shutdown.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked primary heat exchanger, Closed isolation valves on flow/return, Seized or airlocked pump, Sludge in system pipework
How to Fix / Troubleshooting
Safety: Turn off power and allow the boiler to cool completely. Surfaces and water may be very hot.
- Check isolation valves: Ensure the flow and return isolation valves under the Biasi boiler are fully open.
- Verify pump operation: With a heat demand, feel the pump for vibration. If it is hot but not turning, it may be seized. Some pumps have a manual freeing screw that an engineer can use.
- Bleed air: Bleed any automatic or manual air vents near the boiler and on high points in the system to remove airlocks.
- Engineer flushing: If radiators are cold or only warm at the top, sludge may be blocking circulation. A technician may need to powerflush or chemically clean the system and possibly the primary heat exchanger.