16
Biasi
DHW Flow Sensor / Turbine Fault
Boiler displays error 16, often related to domestic hot water flow detection problems.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck or scaled DHW flow turbine, Faulty DHW flow sensor, Blocked inlet filter, Wiring fault to flow sensor
How to Fix / Troubleshooting
Safety: Turn off power and close the cold water inlet to the boiler before removing any DHW components.
- Check DHW demand recognition: Open a hot tap fully and see if the boiler recognises demand (DHW symbol or temperature change on display). If not, suspect the flow sensor.
- Clean inlet filter: On many Biasi combi boilers, there is a filter on the cold inlet. Isolate and remove it, then clean any debris.
- Inspect flow sensor/turbine: Remove the DHW flow sensor housing and check that the turbine spins freely. Descale or replace if jammed.
- Engineer electrical test: A technician should verify the sensor output to the PCB and replace the sensor if no pulses are detected when water flows.