18
Biasi Condensate / Flue Blockage Fault

Boiler displays error 18, often associated with condensate or flue gas recirculation issues.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked condensate trap, Frozen or blocked condensate pipe, Incorrect condensate pipe fall, Flue gas recirculation due to poor flue termination

How to Fix / Troubleshooting

Safety: Isolate power. Condensate is mildly acidic; wear gloves and eye protection when handling.

  • Check condensate pipe externally: Look for freezing or kinks in the plastic condensate pipe, especially outside. Thaw gently with warm water if frozen.
  • Clean condensate trap: Remove the condensate trap from the bottom of the Biasi boiler, empty it, and rinse out any sludge or debris. Refit ensuring seals are correctly seated.
  • Verify pipe fall: Ensure the condensate pipe runs downhill continuously to the drain with no upward loops that could trap water.
  • Engineer flue check: A technician should confirm that the flue terminal is correctly positioned and that there is no recirculation of flue gases into the air intake.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Condensate Trap
Check Price on Amazon