Expansion Vessel / Pressure Rise Fault
Boiler shows error 19, may indicate expansion vessel or pressure-related fault during heating.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed or flat expansion vessel, Blocked connection between vessel and system, Overfilled system pressure, Faulty safety relief valve passing
How to Fix / Troubleshooting
Safety: Allow the system to cool. Hot water under pressure can cause scalding.
- Observe pressure behaviour: Note the cold pressure and the pressure when the system is hot. If it rises above 3 bar and the relief valve discharges, the expansion vessel is likely faulty.
- Check for discharge: Look at the pressure relief valve discharge pipe outside. Dripping indicates overpressure or a passing valve.
- Engineer recharge: A technician can isolate and drain the boiler, then check and recharge the expansion vessel air side to the value specified by Biasi (often around 0.8–1.0 bar).
- Replace vessel if failed: If the diaphragm is ruptured, the expansion vessel must be replaced, and the system refilled and bled.