Biasi Unstable DHW Temperature

Hot water temperature fluctuates between hot and cold during use, especially at low flow rates.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Partially blocked plate heat exchanger, Faulty DHW NTC sensor, Sticking gas valve modulation, Incorrect minimum gas rate setting

How to Fix / Troubleshooting

Safety: Water may suddenly become very hot; take care when testing taps or showers.

  • Test at different taps: Check if the issue occurs at all hot outlets or only one, to rule out local mixer valve problems.
  • Increase flow rate: Run the tap fully open. Many combi boilers, including Biasi, regulate better at higher flow rates.
  • Clean inlet filters: Ensure the cold inlet filter and any strainers are clean to maintain stable flow.
  • Engineer checks: A technician can test the DHW NTC, descale or replace the plate heat exchanger, and verify gas valve modulation and combustion settings.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Plate Heat Exchanger
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements