A8
Bosch DHW Sensor / Control Parameter Fault

Boiler indicates an issue with the hot water sensor or control; DHW may not reach set temperature or may fluctuate.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect DHW sensor calibration, Faulty DHW NTC sensor, Wiring harness fault between DHW NTC and control board, Control board configuration error

How to Fix / Troubleshooting

Safety: Isolate electrical power and close the gas valve before opening the boiler casing.

Diagnostic steps:

  • Check DHW setpoint: Verify the DHW temperature setting on the Bosch user interface. Ensure it is not set too low or in ECO mode if higher temperature is desired.
  • Inspect DHW NTC: Locate the DHW NTC on the hot water outlet or plate heat exchanger. Check for secure mounting and good thermal contact. Loose sensors can cause erratic readings.
  • Measure resistance: With power off, disconnect the NTC and measure resistance. Compare to Bosch spec at room temperature. Replace if out of range.
  • Check harness and plug: Inspect the connector at the sensor and at the PCB for bent pins, corrosion, or broken conductors. Repair or replace harness as needed.
  • Parameter reset: If available on your model, enter installer/service menu and reset DHW parameters to factory defaults (refer to Bosch installation manual). Do not change gas settings.

Professional help: If the sensor and wiring are correct and the fault persists, the main control board may be defective and should be tested and replaced by a qualified Bosch technician.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

DHW NTC Temperature Sensor
Check Price on Amazon