EA
Bosch Ignition Failure / No Flame Detected

Boiler attempts to ignite but fails; you may hear clicking but no flame, then the boiler locks out with EA.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

No gas supply or low gas pressure, Faulty ignition electrode or lead, Faulty flame sensor (ionisation electrode), Blocked burner or injector, Faulty gas valve or ignition control on PCB

How to Fix / Troubleshooting

Safety: If you smell gas, do not attempt to reset the boiler. Turn off the gas at the meter, ventilate the area, and call the gas emergency number and a Gas Safe engineer immediately.

User checks:

  • Confirm that the gas isolation valve to the boiler is open.
  • Check if other gas appliances (hob, fire) work. If none work, there may be a supply issue.
  • Reset the boiler following the Bosch user instructions. Observe whether the boiler tries to ignite (fan runs, clicking heard).

Technician checks (for reference):

  • Inspect and clean the ignition and ionisation electrodes; check gap and condition.
  • Check gas valve operation and inlet pressure.
  • Verify correct polarity and earth on the electrical supply, as flame sensing relies on proper earthing.

Do not attempt to dismantle the burner or gas valve yourself. Ignition and combustion faults must be rectified by a qualified gas engineer.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Ignition Electrode and Ionisation Electrode
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements