F0
Bosch
General Sensor Fault
Boiler shows a general sensor fault; may relate to multiple NTCs or internal sensors.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Multiple NTC sensors out of range, Shared sensor reference fault on PCB, Wiring harness damage affecting several sensors, Control board failure
How to Fix / Troubleshooting
Safety: Isolate power before opening the boiler.
Steps:
- Visual inspection: Look for any obvious damage to sensor wiring looms, especially where they pass near hot components or sharp edges.
- Check all NTC plugs: Reseat the flow, return, DHW, and flue NTC connectors on both the sensors and the PCB.
- Moisture check: Inspect the PCB area for signs of condensation or water ingress. Address any leaks before further operation.
Professional diagnosis: Because this code can indicate PCB‑level issues, a Bosch service engineer should test sensor circuits and replace the control board if necessary.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Main Control PCB
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements