H07
Bosch
Low Water Pressure Fault
Boiler indicates a low system pressure condition; heating may not start.
Advertisements
Possible Causes
Insufficient water in heating circuit, Leak in system pipework or radiators, Faulty pressure sensor, Faulty filling loop not closed properly
How to Fix / Troubleshooting
Safety: Allow the system to cool before topping up. Do not over‑pressurise the boiler.
Steps:
- Check pressure gauge: On the front of the Bosch boiler, note the pressure. If below about 1.0 bar when cold, topping up is required.
- Top up via filling loop: Locate the filling loop (flexible hose or built‑in valves). Open the valves slowly until the pressure rises to 1.0–1.5 bar, then close both valves fully.
- Bleed radiators: Bleed any air from radiators, then recheck pressure and top up again if needed.
- Check for leaks: Inspect visible pipework, radiators, and the boiler underside for signs of water leakage.
If pressure continues to drop, there may be a hidden leak or faulty expansion vessel; a heating engineer should investigate.