Bradford White Intermittent Lockout / Nuisance Shutdown

Boiler frequently locks out and must be manually reset, but no specific code is displayed or retained.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose electrical connections, Marginal flame signal, Intermittent pressure switch operation, Control board intermittently failing

How to Fix / Troubleshooting

Safety first: Turn off power before tightening connections or removing panels.

  • Step 1 – Record conditions: Note when lockouts occur (windy days, long runs, specific zones). This helps identify patterns.
  • Step 2 – Tighten connections: Inspect and snug all low-voltage and line-voltage connections at the control board, gas valve, pressure switch, and sensors.
  • Step 3 – Clean flame sensor: Even if not coded, a weak flame signal can cause intermittent lockouts. Clean the flame sensor rod as described in other entries.
  • Step 4 – Check venting and intake: Ensure vent and intake terminations are clear and properly installed. Wind effects can cause intermittent pressure switch trips.
  • Step 5 – Professional diagnostics: If the problem persists, a technician should monitor flame signal strength, pressure switch operation, and control board behavior during operation.

Note: Repeated manual resets without finding the cause can mask a developing safety issue.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Integrated Boiler Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements